dc.descriptionEl propósito de este trabajo consiste en desarrollar un análisis teórico – experimental mediante normativa y pruebas de laboratorio donde se estudia el comportamiento de las vigas de hormigón armado con traslapes realizados de forma escalonada, empezando de una viga base con geometría tipo predeterminada, que es llevada a un ensayo con una forma simplemente apoyada puesta a una carga puntual en el centro de la viga que determina su deformación. Tiene como objetivo comparar los esfuerzos a flexión por traslape donde se realizaron 3 tipos de vigas, una viga se la realizó sin traslape y la otras dos tienen una configuración de traslape de 0.13 m y 0.08 m, con las siguientes dimensiones de la viga son 0,75 m de longitud, 0.145 m de altura y 0.07 m de ancho, donde el elemento se lo diseño para que el esfuerzo a flexión afecte al acero. Mediante los ensayos realizados en laboratorio nos han permitido comprobar que la resistencia de las vigas ensayadas es mayor que la propuesta por modelos analíticos. Se ha constatado que la resistencia hasta llegar al punto de fisuración propuesta analíticamente es inferior a la obtenida experimentalmente.es_ES
dc.description.abstractThe purpose of this work is to develop a theoretical-experimental analysis through normative and laboratory tests where the behavior of reinforced concrete beams with staggered overlaps is studied, starting from a base beam with predetermined type geometry, which is tested with a simply supported shape placed at a point load in the center of the beam that determines its deformation. The work is to compare the bending stresses by overlapping where 3 types of beams were made, one beam was made without overlapping and the other two have an overlapping configuration of 0.13 m and 0.08 m, with the following dimensions of the beam are 0.75 m long, 0.145 m high and 0.07 m wide, where the element was designed so that the bending stress affects the steel. Laboratory tests have allowed us to verify that the strength of the tested beams is higher than that proposed by analytical models. It has been found that the resistance up to the cracking point proposed analytically is lower than the one obtained experimentally.es_ES
dc.format.extent37 p.es_ES
dc.language.isoeses_ES
dc.rightsopenAccesses_ES
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
dc.subjectHORMIGON ARMADOes_ES
dc.subjectTRASLAPEes_ES
dc.title<B>análisis teórico experimental del comportamiento a flexión de vigas de hormigón armado mediante traslapes ineficientes de forma escalonada</b>es_ES
dc.typebachelorThesises_ES
dc.emailjcvalenciag_est@utmachala.edu.eces_ES
dc.cedula0705629814es_ES
dc.utmachtitulacion.titulacionExamen complexivoes_ES
dc.utmachbibliotecario.bibliotecarioPeralta Mercyes_ES
dc.utmachproceso.procesoPT-171022 (2022-2 TC)es_ES
Aparece en las colecciones: Examen Complexivo Ingeniería Civil

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
VALENCIA GUANGA JEAN CARLOS .pdfEXAMEN COMPLEXIVO3,54 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons