Por favor, use este identificador para citar o enlazar este ítem:
http://repositorio.utmachala.edu.ec/handle/48000/15432
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Aguirre Morales, Fredy Alejandro | - |
dc.contributor.author | Manrique Tenesaca, Andrés Alberto | - |
dc.date.accessioned | 2020-03-11T18:59:09Z | - |
dc.date.available | 2020-03-11T18:59:09Z | - |
dc.date.issued | 2020 | - |
dc.identifier.other | ECFIC-2020-IC-DE-00014 | - |
dc.identifier.uri | http://repositorio.utmachala.edu.ec/handle/48000/15432 | - |
dc.description | El presente trabajo muestra conceptos importantes sobre la utilización de filtros de gravedad autónomos sin válvulas, para el tratamiento de agua potable, como objeto de estudio, aplicación y funcionamiento tenemos la planta de tratamiento de agua potable San José, que abastece a la ciudad de Portovelo y que cuenta con dos unidades de filtración de este tipo. En el desarrollo de este trabajo se realizó la evaluación de los parámetros operacionales de los filtros y comprobó su eficiencia dentro del proceso de remoción de la turbiedad, donde se pudo verificar que el agua tratada cumple con los parámetros permitidos siendo apta para el consumo humano, manteniéndose sus valores dentro del límite tolerable dispuesto por el Instituto Ecuatoriano de Normalización en su Norma Técnica Ecuatoriana 1108 para la remoción de la turbiedad, aunque sus valores son un poco altos a diferencia de otro tipo de filtros, esto debido a la presencia de gran cantidad de partículas y sólidos disueltos en el agua captada en épocas de invierno y a la falta de mantenimiento en las operaciones previas al proceso de filtración. También se llevó a cabo un control del lavado de los filtros para determinar la duración de las carreras de filtración determinando que el intervalo de lavado es de 36 horas en invierno y de 73 horas en verano aproximadamente y que la duración de cada lavado es de 4 min. Los filtros operan con una velocidad de filtración de 138.24 𝑚3 𝑚². 𝑑. | es_ES |
dc.description.abstract | The present work shows important concepts about the use of autonomous gravity filters without valves, for the treatment of drinking water, as an object of study, application and operation we have the San José drinking water treatment plant, which supplies the city from Portovelo and it has two filtration units of this type. In the development of this work, the evaluation of the operational parameters of the filters was carried out and their efficiency was verified within the turbidity removal process, where it was possible to verify that the treated water complies with the allowed parameters being suitable for human consumption, keeping its values within the tolerable limit provided by the Ecuadorian Institute for Standardization in its Ecuadorian Technical Standard 1108 for the removal of turbidity, although its values are a bit high unlike other types of filters, this due to the presence of large numbers of particles and solids dissolved in the water collected in winter and the lack of maintenance in the operations prior to the filtration process. A filter wash control was also carried out to determine the duration of the filtration runs by determining that the wash interval is 36 hours in winter and approximately 73 hours in summer and that the duration of each wash is 4 min. The filters operate with a filtration rate of 138.24 𝑚3 𝑚². 𝑑 | es_ES |
dc.format.extent | 66 p. | es_ES |
dc.language.iso | es | es_ES |
dc.rights | openAccess | es_ES |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/3.0/ec/ | es_ES |
dc.subject | FILTRO | es_ES |
dc.subject | RETROLAVADO | es_ES |
dc.subject | AUTOLIMPIANTE | es_ES |
dc.subject | CARRERA DE FILTRACION | es_ES |
dc.title | Evaluación de los filtros de gravedad autónomos sin válvulas de la planta de tratamiento de agua potable de Portovelo | es_ES |
dc.type | Examen Complexivo | es_ES |
dc.email | amanrique_est@utmachala.edu.ec | es_ES |
dc.cedula | 0706450517 | es_ES |
dc.utmachtitulacion.titulacion | Examen complexivo | es_ES |
dc.utmachbibliotecario.bibliotecario | Peralta Mercy | es_ES |
dc.utmachproceso.proceso | PT-011119 (2019-2) | es_ES |
Aparece en las colecciones: | Examen Complexivo Ingeniería Civil |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
ECFIC-2020-IC-DE-00014.pdf | EXAMEN COMPLEXIVO | 10,43 MB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons