DSpace logo

Por favor, use este identificador para citar o enlazar este ítem: http://repositorio.utmachala.edu.ec/handle/48000/18698
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorAguirre Morales, Fredy Alejandro-
dc.contributor.authorMontaño Fernández, Cleider Joel-
dc.date.accessioned2022-03-10T16:50:15Z-
dc.date.available2022-03-10T16:50:15Z-
dc.date.issued2022-
dc.identifier.otherECFIC-2022-IC-DE00025-
dc.identifier.urihttp://repositorio.utmachala.edu.ec/handle/48000/18698-
dc.descriptionEn este trabajo práctico se tuvo como objetivo elaborar el diseño hidrosanitario para un edificio de 3 pisos, de acuerdo con el Capítulo 16 – Norma Hidrosanitaria NHE Agua NEC-11. El edificio está ubicado en el centro de la ciudad de Santa Rosa, en las calles Cuenca y Filomeno Pesantez, donde se realizó lecturas de presiones de 3 m.c.a., presión menor a la requerida por la norma, por ello se decidió implementar un sistema indirecto tradicional, este sistema consta con una cisterna, una bomba y un tanque elevado. Se realizó el cálculo de la dotación requerida considerando el tipo de edificación, de donde se obtuvo 33939,1 Litros/día. Se dimensionó la cisterna y tanque elevado para el 60 y 40% del volumen de dotación respectivamente, obteniendo una cisterna con una capacidad de almacenamiento de 2,85 m3 y el tanque elevado de 1,5 m3. Para saber cuál era la bomba idónea se realizó el cálculo de pérdidas menores y por fricción para el sistema de succión e impulsión. Según la curva del sistema se seleccionó una bomba de 0,7 HP. Se realizaron los planos correspondientes según los resultados de las redes de agua potable donde se colocaron diámetros de 1 1/4 y de ¾ de pulgada, para la red aguas servidas se utilizó diámetros de 2 y 4 pulgadas y cuatro bajantes. Para aguas lluvias se empleó diámetros de 3 pulgadas y se colocaron 2 bajantes. También realizó la isometría de la red de agua y el sistema de bombeo empleado.es_ES
dc.description.abstractIn this practical work, the objective was to elaborate the hydrosanitary design for a 3-story building, in accordance with Chapter 16 – NHE Water Hydrosanitary Standard NEC-11. The building is located in the center of the city of Santa Rosa, on Cuenca and Filomeno Pesantez streets, where pressure readings of 3 mca were made, a pressure lower than that required by the standard, for which it was decided to implement a traditional indirect system. , this system consists of a tank, a pump and an elevated tank. The calculation of the required amount was made considering the type of building, from which 33939.1 liters/day were obtained. The cistern and elevated tank were sized for 60 and 40% of the supply volume, respectively, obtaining a cistern with a storage capacity of 2.85 m3 and the elevated tank of 1.5 m3. In order to know which was the ideal pump, the calculation of minor and friction losses was carried out for the suction and impulsion system. According to the system curve, a 0.7 HP pump was selected. The corresponding plans were made according to the results of the drinking water networks where diameters of 1 1/4 and ¾ inches were placed, for red water served, diameters of 2 and 4 inches and four downspouts were obtained. For rainwater, 3-inch diameters were used and 2 downspouts were placed. He also made the isometry of the water network and the pumping system used.es_ES
dc.format.extent41 p.es_ES
dc.language.isoeses_ES
dc.rightsopenAccesses_ES
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
dc.subjectRED DE AGUA POTABLEes_ES
dc.subjectEDIFICIOes_ES
dc.subjectBOMBAes_ES
dc.subjectSISTEMA INDIRECTOes_ES
dc.titleDiseño hidrosanitario de un edificio de tres pisos ubicado en la ciudad de Santa Rosa, provincia de El Oro.es_ES
dc.typeExamen Complexivoes_ES
dc.emailcjmontano_est@utmachala.edu.eces_ES
dc.cedula0704662139 cjmontano_est@utmachala.edu.eces_ES
dc.utmachtitulacion.titulacionExamen complexivoes_ES
dc.utmachbibliotecario.bibliotecarioPeralta Mercyes_ES
dc.utmachproceso.procesoPT-041021 (2021-2)es_ES
Aparece en las colecciones: Examen Complexivo Ingeniería Civil

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
ECFIC-2022-IC-DE00025.pdfEXAMEN COMPLEXIVO1,96 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons