DSpace logo

Por favor, use este identificador para citar o enlazar este ítem: http://repositorio.utmachala.edu.ec/handle/48000/18672
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorZarate Encalada, Josè Marcelo-
dc.contributor.authorLoja León, Edwin Steven-
dc.date.accessioned2022-03-09T18:23:47Z-
dc.date.available2022-03-09T18:23:47Z-
dc.date.issued2022-
dc.identifier.otherECFIC-2022-IC-DE00023-
dc.identifier.urihttp://repositorio.utmachala.edu.ec/handle/48000/18672-
dc.descriptionEl objetivo de este trabajo es evaluar la vulnerabilidad sísmica de un bloque de la unidad educativa Dr. José Ochoa León, ubicado en la ciudad de Pasaje de la provincia de EL Oro, a través de una evaluación, Rapid Visual Screening, RVS que proporciona la Agencia Federal para la Gestión de Emergencias de los Estados Unidos, Federal Emergency Management Agency, FEMA P-154. Esta metodología se basa en hacer un chequeo visual de la edificación para la recolección de los datos necesarios que requieran los formularios que proporciona la FEMA P-154.La elección de los formularios van acorde a la región sísmica, los mismo que comprenden en sismicidad baja, moderada y alta, dependiendo la ubicación de la estructura que se va analizar. El puntaje final, S, del análisis de la estructura, se obtiene de la suma o resta de cada uno de los modificadores de puntaje que varían de acuerdo al formulario, luego de obtener el valor final. Si el índice obtenido resulta menor o igual que dos, debe ser evaluado a mayor detalle o en caso de ser mayor que dos, se considera que la vulnerabilidad sísmica de la estructura es baja. Para obtener los valores de aceleración en roca, se debe vincular la FEMA P-154 con la Norma Ecuatoriana de construcción de Riesgo Sísmico, Evaluación, Rehabilitación de Estructuras, NEC-SE-RE, y Peligro sísmico y Diseño sismo resistente, NEC-SE-DS, ya que la FEMA P-154 brinda otros valores de respuesta de aceleración en roca, lo cual permite elegir la región sísmica adecuada.es_ES
dc.description.abstractThe objective of this work is to evaluate the seismic vulnerability of a block of the educational unit Dr. José Ochoa León, located in the city of Pasaje in the province of El Oro, through a Rapid Visual Screening, RVS evaluation provided by the Federal Emergency Management Agency of the United States, FEMA P-154. This methodology is based on making a visual check of the building for the collection of the necessary data required by the forms provided by FEMA P-154. The choice of the forms is according to the seismic region, which include low, moderate and high seismicity, depending on the location of the structure to be analyzed. The final score, S, of the analysis of the structure, is obtained from the sum or subtraction of each of the score modifiers that vary according to the form, after obtaining the final value. If the index obtained is less than or equal to two, it must be evaluated in greater detail or if it is greater than two, the seismic vulnerability of the structure is considered to be low. To obtain the rock acceleration values, FEMA P-154 should be linked to the Ecuadorian Construction Standard on Seismic Risk, Evaluation, Rehabilitation of Structures,NEC-SE-RE and Seismic Hazard and Seismic Resistant Design, NEC-SE-DS, since FEMA P-154 provides other rock acceleration response values, which allows choosing the appropriate seismic regiones_ES
dc.format.extent46 p.es_ES
dc.language.isoeses_ES
dc.rightsopenAccesses_ES
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
dc.subjectVULNERABILIDAD SISMICAes_ES
dc.subjectVULNERABILIDAD ESTRUCTURALes_ES
dc.subjectFEMA P-154es_ES
dc.subjectRIESGO SISMICO.es_ES
dc.titleEvaluación de vulnerabilidad sísmica del colegio de bachillerato “Dr. José Ochoa León” aplicando la metodología fema p-154 y neces_ES
dc.typeExamen Complexivoes_ES
dc.emaileloja_est@utmachala.edu.eces_ES
dc.cedula0705945418es_ES
dc.utmachtitulacion.titulacionExamen complexivoes_ES
dc.utmachbibliotecario.bibliotecarioPeralta Mercyes_ES
dc.utmachproceso.procesoPT-041021 (2021-2)es_ES
Aparece en las colecciones: Examen Complexivo Ingeniería Civil

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
ECFIC-2022-IC-DE00023.pdfEXAMEN COMPLEXIVO1,9 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons