Por favor, use este identificador para citar o enlazar este ítem:
http://repositorio.utmachala.edu.ec/handle/48000/17874
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Aguirre Morales, Fredy Alejandro | - |
dc.contributor.author | Ramón Patiño, Máximo Manuel | - |
dc.date.accessioned | 2021-10-20T17:38:25Z | - |
dc.date.available | 2021-10-20T17:38:25Z | - |
dc.date.issued | 2021 | - |
dc.identifier.citation | Ramón Patiño, Máximo Manuel. (2021) Evaluación del sistema de alcantarillado sanitario del recinto San Carlos I y II del cantón Balao (trabajo de titulación). UTMACH, Facultad de Ingeniería Civil, Machala, Ecuador. | es_ES |
dc.identifier.other | TTFIC-2021-IC-DE00003 | - |
dc.identifier.uri | http://repositorio.utmachala.edu.ec/handle/48000/17874 | - |
dc.description | En el Ecuador los sistemas de tratamiento de aguas residuales tienen un porcentaje bajo de cobertura, y en los lugares donde existen no se hace una evaluación íntegra sino parcial. La provincia que trata de mejor forma las aguas residuales es Azuay, y última la ciudad de Ibarra con una planta de lodos activados. Existen varios tipos de sistemas de tratamiento para aguas residuales, esto depende de factores, como el número de habitante, clima, tipo de carga contaminante, caudal, y el tema de presupuesto, entre ellas las lagunas de estabilización que por su bajo costo en operación ha sido utilizada en la parte urbana como rural de nuestro país, este tipo de tratamiento es el que existe en el recinto San Carlos del cantón Balao lugar donde se desarrolló la investigación. Este trabajo se planteó con el fin de recabar información bibliográfica y de campo que permita evaluar el funcionamiento del sistema de alcantarillado, que a la fecha de evaluación se encuentra a un poco menos de la mitad del del periodo de diseño, verificando los parámetros de calidad del agua en el efluente para compararlos con los de la Norma Ambiental (Libro VI anexo 1) y determinar si la planta está cumpliendo con los parámetros mínimos permitidos, en cuanto a la descarga de aguas servidas en cuerpos receptores de agua dulce, que luego es utilizado para riego del sector agrícola de la zona. La parte hidráulica de recolección de aguas servidas y el sistema de bombeo se compararon con la norma CPE INEN 5 Parte 9-1, 1992, para lo cual se utilizó métodos de investigación bibliográfica e investigación de campo. Una parte de la información bibliográfica del sistema, la obtuvimos mediante oficio previo al departamento de planificación y alcantarillado sanitario del municipio del cantón Balao, información que no se encuentra directamente en el portal de compras públicas. Los datos adicionales del sitio se obtuvieron mediante una serie de trabajos en el campo, tales como: nivelación geométrica para conocer las cotas del terreno, medición de profundidad, distancias, pendientes, diámetro de tuberías de los pozos principales. En el sistema de bombeo se verificó las dimensiones, las características de la bomba instalada, y se realizó los aforos con el método volumétrico para determinar el caudal de bombeo. En la planta de tratamiento se realizó aforos, para determinar el caudal de entrada utilizando el método de vertedero sin contracción, se verificó las dimensiones, se calculó volumen de agua y lodos, tanto en la laguna facultativa como en la de maduración. En el cuerpo receptor se realizó aforos mediante el método de flotador para determinar su caudal, se comparó la carga contaminante de entrada, así como los parámetros que se debe cumplir en la descarga con la norma ambiental, y de esta forma poder cuantificar la eficiencia de la planta. Se pudo concluir que el sistema de tratamiento en general cumple con las disposiciones establecidas en las normativas, tanto de diseño como la normativa ambiental, y en los parámetros que no cumplió se realizó las observaciones respectivas del caso. | es_ES |
dc.description.abstract | In Ecuador, wastewater treatment systems have a low percentage of coverage, and in places where they exist, a full but partial evaluation is not made. The province that best treats wastewater is Azuay, and last the city of Ibarra with an activated sludge plant. There are several types of treatment systems for wastewater, this depends on factors, such as the number of inhabitant, climate, type of pollutant load, flow, and the budget issue, including the stabilization lagoons that due to its low cost in operation has been used in the urban and rural part of our country, this type of treatment is the one that exists in the San Carlos enclosure of the Balao canton where it was developed research. This work was proposed in order to collect bibliographic and field information to evaluate the operation of the sewerage system, which at the date of evaluation is a little less than half of the design period, verifying the parameters of water quality in the effluent to compare them with those of the Environmental Standard (Book VI annex 1) and determine if the plant is complying with the parameters minimum allowed, in terms of the discharge of wastewater into freshwater receiving bodies, which is then used for irrigation of the agricultural sector of the area. The hydraulic part of wastewater collection and the pumping system were compared with the CPE INEN 5 Part 9-1,1992 standard, for which bibliographic research and field research methods were used. A part of the bibliographic information of the system, we obtained it by means of a previous letter to the department of planning and sanitary sewerage of the municipality of the canton Balao, information that is not directly in the portal of public purchases. Additional data from the site were obtained through a series of works in the field, such as: geometric leveling to know the heights of the terrain, depth measurement, distances, slopes, diameter of pipes of the main wells. In the pumping system, the dimensions and characteristics of the installed pump were verified, and the capacity was carried out with the volumetric method to determine the pumping flow. In the treatment plant, capacity was carried out to determine the inflow rate using the landfill method without contraction, the dimensions were verified, the volume of water and slurt was calculated, both in the facultative lagoon and in the maturation lagoon. In the receiving body, capacity was carried out using the float method to determine its flow, the inlet pollutant load was compared, as well as the parameters that must be met in the discharge with the environmental standard, and in this way be able to quantify the efficiency of the plant. It was possible to conclude that the treatment system in general complies with the provisions established in the regulations, both design and environmental regulations, and in the parameters that it did not comply with, the respective observations of the case were made. | es_ES |
dc.format.extent | 72 p. | es_ES |
dc.language.iso | es | es_ES |
dc.publisher | Machala: Universidad Técnica de Machala | es_ES |
dc.rights | openAccess | es_ES |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/3.0/ec/ | es_ES |
dc.subject | PLANTAS DE TRATAMIENTO | es_ES |
dc.subject | AGUA RESIDUAL | es_ES |
dc.subject | LAGUNA DE ESTABILIZACIÓN | es_ES |
dc.subject | ESTACIÓN DE BOMBEO | es_ES |
dc.title | Evaluación del sistema de alcantarillado sanitario del recinto San Carlos I y II del cantón Balao | es_ES |
dc.type | bachelorThesis | es_ES |
dc.email | mmramonp_est@utmachala.edu.ec | es_ES |
dc.cedula | 0929771889 | es_ES |
dc.utmachtitulacion.titulacion | Análisis de casos | es_ES |
dc.utmachbibliotecario.bibliotecario | Peralta Mercy | es_ES |
dc.utmachproceso.proceso | PT-170521 (2021-1) | es_ES |
Aparece en las colecciones: | Trabajo de Titulación Ingeniería Civil |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
TTFIC-2021-IC-DE00003.pdf | TRABAJO DE TITULACION | 9,72 MB | Adobe PDF | Visualizar/Abrir |