DSpace logo

Por favor, use este identificador para citar o enlazar este ítem: http://repositorio.utmachala.edu.ec/handle/48000/16768
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorYanez Romero, María Elena-
dc.contributor.authorValdez Marquez, Santos Jefferson-
dc.date.accessioned2021-05-18T01:56:05Z-
dc.date.available2021-05-18T01:56:05Z-
dc.date.issued2021-
dc.identifier.citationValdez Marquez, S.J. (2021) Determinación de la mezcla optima de carbón para disminuir la contaminación ambiental en la planta “electric coop” mediante programación lineal. (examen complexivo). UTMACH, Facultad De ciencias Químicas Y De La Salud, Machala, Ecuador. 26 p.es_ES
dc.identifier.otherECUACQS-2021-IQ-DE00020-
dc.identifier.urihttp://repositorio.utmachala.edu.ec/handle/48000/16768-
dc.descriptionEl objetivo de este trabajo es determinar la mezcla óptima de carbón pulverizado para disminuir la contaminación ambiental en la planta “Electric Coop”, y que cumpla con los parámetros de descarga de bióxido de azufre y humo de chimenea, establecidos en Norma de la Agencia de Protección Ambiental. Para lo cual, se empleó el método Gráfico y método Simplex que determina la cantidad de carbón pulverizado C1 y C2 requeridos en la mezcla, la misma que generará la máxima cantidad de vapor de turbina para la planta Electric Coop. Bajo el método Grafico se obtuvieron tres puntos factibles: punto A (0;0), punto B (5,13; 10,26), punto C (9,52; 0), siendo el punto B el mejor resultado, debido a que la mezcla de 5,13 C1 y 10,26 de C2, generan 153900 libras de vapor por hora. Mientras que, aplicando el método Simplex, la mezcla de 5,12 de C1 y 10,24 de C2, produce 153600 libras de vapor por hora.es_ES
dc.description.abstractThe objective of this work is to determine the optimal mixture of pulverized coal to reduce environmental pollution in the "Electric Coop" plant, and to comply with the parameters of sulfur dioxide discharge and chimney smoke, established in the Environmental Protection Agency Standard. For this purpose, the Graphical method and Simplex method were used to determine the amount of pulverized coal C1 and C2 required in the mixture, which will generate the maximum amount of turbine steam for the Electric Coop plant. Under the Graphical method, three feasible points were obtained: point A (0;0), point B (5.13; 10.26), point C (9.52; 0), being point B the best result, because the mixture of 5.13 C1 and 10.26 of C2, generate 153900 pounds of steam per hour. While, applying the Simplex method, the mixture of 5.12 of C1 and 10.24 of C2, produces 153600 pounds of steam per hour.es_ES
dc.format.extent26 p.es_ES
dc.language.isoeses_ES
dc.publisherMachala : Universidad Técnica de Machalaes_ES
dc.rightsopenAccesses_ES
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
dc.subjectPROGRAMACION LINEALes_ES
dc.subjectCONTAMINACION AMBIENTALes_ES
dc.subjectMAXIMIZACIONes_ES
dc.subjectENERGIAes_ES
dc.titleDeterminación de la mezcla optima de carbón para disminuir la contaminación ambiental en la planta “electric coop” mediante programación lineal.es_ES
dc.typeExamen Complexivoes_ES
dc.emailsvaldez_est@utmachala.edu.eces_ES
dc.emailmyanez@utmachala.edu.eces_ES
dc.cedula0704459478es_ES
dc.cedula0704077544es_ES
dc.utmachtitulacion.titulacionExamen complexivoes_ES
dc.utmachbibliotecario.bibliotecarioAlvarado Jazmanyes_ES
dc.utmachproceso.procesoPT-141220 (2020-2)es_ES
Aparece en las colecciones: Examen Complexivo Ingeniería Química

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
E-9544_VALDEZ MARQUEZ SANTOS JEFFERSON.pdfExamen Complexivo1,71 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons