DSpace logo

Por favor, use este identificador para citar o enlazar este ítem: http://repositorio.utmachala.edu.ec/handle/48000/15442
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorZarate Encalada, José Marcelo-
dc.contributor.authorPacho Cruz ,Ángel Patricio-
dc.date.accessioned2020-03-11T19:41:29Z-
dc.date.available2020-03-11T19:41:29Z-
dc.date.issued2020-
dc.identifier.otherECFIC-2020-IC-DE-00017-
dc.identifier.urihttp://repositorio.utmachala.edu.ec/handle/48000/15442-
dc.descriptionEl presente trabajo tiene como planteamiento Evaluar la vulnerabilidad sísmica de un bloque de la unidad educativa Dr. Manuel A. González perteneciente al cantón Pasaje de la Provincia de El Oro, esta evaluación se basa en un Examen de Visualización Rápida Rapid Visual Screening RVS propuesto por la Agencia Federal para la Gestión de Emergencias Federal Emergency Management Agency FEMA P-154 dirigidos para 17 tipos de estructuras establecidos en unos de los 5 niveles de regiones sísmicas categorizadas por la metodología. El sistema de puntuación se basa en una suma algebraica de valores pertenecientes a los modificadores de calificación que propone el catalogo, el resultado final será comparado con la puntuación básica de 2, siendo este un valor máximo en la consideración de edificios con un bajo rendimiento al desempeño sísmico y del cual deben ser considerados para una evaluación estructural más minuciosa del inmueble, aquellos resultados con un valor mayor a la puntuación básica tienen un mejor desempeño sísmico. Sin embargo, dentro del formulario de evaluación existe algunos parámetros de calificación que involucran la presencia de riesgos potenciales que amenazan con la vulnerabilidad estructural interna y externa del inmueble. La aplicación de la metodología FEMA P-154 se sustentará con la aplicación de la Normativa Ecuatoriana de construcción de Riesgo Sísmico, Evaluación, Rehabilitación de Estructuras NEC-SE-RE, en la norma de Peligro sísmico y Diseño sismo resistente NEC-SE-DS, puesto que la determinación de la región sísmica de Estados Unidos tiene otrases_ES
dc.description.abstractThe present work has as an approach Evaluate the seismic modification of a block of the educational unit Dr. Manuel A. González belonging to the Passage canton of the Province of El Oro, this evaluation is based on an RVS Rapid Visualization Test proposed by the Agency Federal for Emergency Management Federal Agency for Emergency Management FEMA P-154 aimed at 17 types of structures established in the 5 levels of seismic regions categorized by the methodology. The scoring system is based on an algebraic sum of values belonging to the rating modifiers proposed by the catalog, the final result will be compared with the basic score of 2, this being a maximum value in the measurement of buildings with poor performance. Seismic and which should be considered for a more thorough structural evaluation of the property, those results with a value greater than the basic score have a better seismic performance. However, within the evaluation form there are some qualification parameters that involve the presence of risks that may be affected by the internal and external structural threats of the property. The application of the FEMA P-154 methodology will be supported by the application of the Ecuadorian Standard for Seismic Risk Construction, Evaluation, Rehabilitation of Structures NEC-SE-RE, in the norm of Seismic Hazard and Earthquake Resistant Design (EC- SE-DS, since the determination of the seismic region of the United States has other considerations for finding the acceleration response values in rock.es_ES
dc.format.extent50 p.es_ES
dc.language.isoeses_ES
dc.rightsopenAccesses_ES
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
dc.subjectVULNERABILIDAD SISMICAes_ES
dc.subjectREGION SISMICAes_ES
dc.subjectDESEMPEÑO SISMICOes_ES
dc.subjectVULNERABILIDAD ESTRUCTURALes_ES
dc.titleVulnerabilidad sísmica de la Unidad Educativa Dr. Manuel A. González aplicando la metodología fema 154 y Normativa Ecuatoriana de Construcciónes_ES
dc.typeExamen Complexivoes_ES
dc.emailapacho_est@utmachala.edu.eces_ES
dc.cedula0706646320es_ES
dc.utmachtitulacion.titulacionExamen complexivoes_ES
dc.utmachbibliotecario.bibliotecarioPeralta Mercyes_ES
dc.utmachproceso.procesoPT-011119 (2019-2)es_ES
Aparece en las colecciones: Examen Complexivo Ingeniería Civil

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
ECFIC-2020-IC-DE-00017.pdfEXAMEN COMPLEXIVO20,55 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons