DSpace logo

Por favor, use este identificador para citar o enlazar este ítem: http://repositorio.utmachala.edu.ec/handle/48000/13537
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorOrdóñez Fernández, José Luis-
dc.contributor.authorMatamoros Benavides, Richard De Jesus-
dc.date.accessioned2019-02-12T19:55:55Z-
dc.date.available2019-02-12T19:55:55Z-
dc.date.issued2019-
dc.identifier.urihttp://repositorio.utmachala.edu.ec/handle/48000/13537-
dc.descriptionEn el presente trabajo se realiza el análisis estructural del “Hospital del IESS” del canton Zaruma basándonos a una filosofía de diseño sismo resistente como lo establece la NEC_SE_DS sección 4.2, que permite demostrar el nivel de seguridad, el sismo de diseño se lo realizo para un periodo de retorno de 475 años. El espectro elástico de diseño depende del tipo de suelo, zona sísmica, la región en donde se realizará la construcción para el valor de n, el valor de r depende del tipo de suelo y demás valores Fa, Fd, Fs son tomados como lo especifica la NEC_SD_DS sección 3.2.2, para el cálculo de To y Tc que son los periodos límites de vibración. Calculamos el cortante basal, en el que utilizamos un factor de reducción sísmica que según la NEC corresponde a la tipología estructural, pero que también debemos tomar en criterio de acuerdo al tipo de secciones y su ductilidad. Se utilizó la norma AISC 360-10 para el chequeo de los elementos estructurales como lo son vigas y columnas dependiendo el tipo de sección. En el software ETABS realizamos el modelado de la estructura, ingresamos valores de carga viva, carga muerta sobre cargas, carga sísmica y combinaciones de carga obtenidas de las NEC_SE_CG sección 3.4.3; obtenemos la deriva máxima de piso que no debe sobrepasar el límite de deriva inelástica del 2% según la sección 4.2.2 de la NEC_SE_DS de igual manera obtenemos los valores del cortante basal y así procedemos a realizar la respectiva corrección.es_ES
dc.description.abstractIn the present work, the structural analysis of the "IESS Hospital" of Zaruma canton is carried out based on a resistant earthquake design philosophy as established in NEC_SE_DS section 4.2, which allows to demonstrate the level of safety, the design earthquake was performed for a return period of 475 years. The elastic spectrum of design depends on the type of soil, seismic zone, the region where the construction will take place for the value of n, the value of r depends on the type of soil and other values Fa, Fd, Fs are taken as specified the NEC_SD_DS section 3.2.2, for the calculation of To and Tc which are the limiting periods of vibration. We calculate the basal shear, in which we use a seismic reduction factor that according to the NEC corresponds to the structural typology, but that we must also take into account according to the type of sections and their ductility. The AISC 360-10 standard was used to check the structural elements such as beams and columns depending on the type of section. In the ETABS software we carry out the modeling of the structure, we enter values of live load, dead load on loads, seismic load and load combinations obtained from the NEC_SE_CG section 3.4.3; we obtain the maximum floor drift that must not exceed the inelastic drift limit of 2% according to section 4.2.2 of the NEC_SE_DS, in the same way we obtain the values of the basal shear and so we proceed to perform the respective correction.es_ES
dc.format.extent52 p.es_ES
dc.language.isoeses_ES
dc.rightsopenAccesses_ES
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
dc.subjectESTRUCTURAes_ES
dc.subjectCARGAes_ES
dc.subjectESPECTROes_ES
dc.subjectCORTANTEes_ES
dc.titleAnálisis estructural de la edificación del hospital del IESS Cantón Zaruma bloque b1es_ES
dc.typeExamen Complexivoes_ES
dc.emailrmatamoros_est@utmachala.edu.eces_ES
dc.cedula0705639292es_ES
dc.utmachtitulacion.titulacionExamen complexivoes_ES
dc.utmachbibliotecario.bibliotecarioPeralta Mercyes_ES
dc.utmachproceso.procesoPT-011018 (2018-2)es_ES
Aparece en las colecciones: Examen Complexivo Ingeniería Civil

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
ECUAIC-2019-ICI-DE00005.pdfEXAMEN COMPLEXIVO3,65 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons