Por favor, use este identificador para citar o enlazar este ítem:
http://repositorio.utmachala.edu.ec/handle/48000/12592
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Agudo Gonzabay, Brigida Maritza | - |
dc.contributor.author | Echeverria Ordoñez, Walter Javier | - |
dc.date.accessioned | 2018-07-19T19:29:27Z | - |
dc.date.available | 2018-07-19T19:29:27Z | - |
dc.date.issued | 2018 | - |
dc.identifier.citation | Echeverria Ordoñez, W.J. (2018) Interpretación del monitoreo electronico intraparto mediante analisis computarizado versus análisis visual en la acidemia fetal. (examen complexivo). UTMACH, Unidad Académica de Ciencias Químicas y de la Salud, Machala, Ecuador. | es_ES |
dc.identifier.other | ECUACQS-2018-M-DE00155 | - |
dc.identifier.uri | http://repositorio.utmachala.edu.ec/handle/48000/12592 | - |
dc.description | El monitoreo electrónico fetal sigue siendo hasta la actualidad la única herramienta para la detección de acidemia, hipoxia, sin embargo no se ha logrado disminuir con este examen la incidencia de morbimortalidad de hipoxia fetal por lo que ha surgido diversos criterios en la interpretación de la monitorización dadas estas por un análisis visual o análisis computarizado, se debe tener en cuenta que ninguna de estas herramientas por si sola ha demostrado una especificidad para la acidemia. Objetivo: Comparar el tipo de monitoreo fetal que detecte con mayor precisión la acidemia e hipoxia mediante la recopilación de artículos científicos sobre el análisis visual o computarizado de este estudio biofísico. Método: Este estudio de tipo sistemático, se realizó una búsqueda en base de datos: ScienceDirect, Springer, Redalyc, Medline, Google académico, desde hace 5 años atrás. Cabe mencionar que esta búsqueda incluyo estudios de cohortes descriptivas, estudio de casos y controles. ensayos de controles aleatorizados. Conclusión: Se puede concluir en este trabajo que las estadísticas de la encefalopatía hipóxico-isquémica continúa afectando a los neonatos en todo el mundo, sin reducir significativamente este problema, que se tenía como objetivo la disminución de esta patología tras la introducción del Monitoreo Fetal Electrónico, por lo que creo que no debe utilizarse un solo método para el diagnóstico de la acidemia, si no combinarlos para reducir la cantidad de bebes acidemicos. | es_ES |
dc.description.abstract | Fetal electronic monitoring is still the only tool for the detection of acidemia, hypoxia, however it has not been possible to reduce the incidence of fetal hypoxia morbidity and mortality with this test, which has led to several criteria in the interpretation of monitoring Given these by a visual analysis or computerized analysis, it should be taken into account that none of these tools alone has demonstrated a specificity for acidemia, another inconvenience that health professionals have when their interpretation is that despite have some guides that are updated every year, none of them reach a consensus regarding the classification of decelerations making it even more difficult to understand them. Objective: To compare the type of fetal monitoring that more accurately detects acidemia and hypoxia through the collection of scientific articles on the visual or computer analysis of this biophysical study. Method: This systematic study was conducted a database search: ScienceDirect, Springer, Redalyc, Medline, Google academic, 5 years ago. It is worth mentioning that this search included descriptive cohort studies, case studies and controls. randomized control trials. Conclusion: It can be concluded in this study that the statistics of hypoxic-ischemic encephalopathy continues to affect neonates throughout the world, without significantly reducing this problem, which aimed to reduce this pathology after the introduction of Electronic Fetal Monitoring, so I think that a single method should not be used for the diagnosis of acidemia, if not combine them to reduce the number of acidemic babies | es_ES |
dc.format.extent | 24 p. | es_ES |
dc.language.iso | es | es_ES |
dc.publisher | Machala : Universidad Técnica de Machala | es_ES |
dc.rights | openAccess | es_ES |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/3.0/ec/ | es_ES |
dc.subject | MONITOREO FETAL | es_ES |
dc.subject | ANALISIS VISUAL | es_ES |
dc.subject | ANALISIS COMPUTARIZADO | es_ES |
dc.subject | DESACELERACIONES | es_ES |
dc.title | Interpretación del monitoreo electrónico intraparto mediante análisis computarizado versus análisis visual en la acidemia fetal. | es_ES |
dc.type | Examen Complexivo | es_ES |
dc.email | wecheverria_est@utmachala.edu.ec | es_ES |
dc.email | bagudo@utmachala.edu.ec | es_ES |
dc.cedula | 0704449693 | es_ES |
dc.cedula | 0908356942 | es_ES |
dc.utmachtitulacion.titulacion | Examen complexivo | es_ES |
dc.utmachbibliotecario.bibliotecario | Alvarado Jazmany | es_ES |
dc.utmachproceso.proceso | PT-010518 (2018-1) | es_ES |
Aparece en las colecciones: | Examen Complexivo Ciencias Médicas |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
E-10168_ECHEVERRIA ORDOÑEZ WALTER JAVIER.pdf | Examen complexivo | 2,15 MB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons