Repositorio Dspace

<B>análisis teórico experimental del comportamiento a flexión de vigas de hormigón armado mediante traslapes ineficientes de forma escalonada</b>

Mostrar el registro sencillo del ítem

dc.contributor.advisor Zarate Encalada, José Marcelo
dc.contributor.author Valencia Guanga, Jean Carlos Manuel
dc.date.accessioned 2023-03-14T18:43:45Z
dc.date.available 2023-03-14T18:43:45Z
dc.date.issued 2023-03
dc.identifier.other ECFIC-2023-IC-DE00042
dc.identifier.uri http://repositorio.utmachala.edu.ec/handle/48000/20785
dc.description El propósito de este trabajo consiste en desarrollar un análisis teórico – experimental mediante normativa y pruebas de laboratorio donde se estudia el comportamiento de las vigas de hormigón armado con traslapes realizados de forma escalonada, empezando de una viga base con geometría tipo predeterminada, que es llevada a un ensayo con una forma simplemente apoyada puesta a una carga puntual en el centro de la viga que determina su deformación. Tiene como objetivo comparar los esfuerzos a flexión por traslape donde se realizaron 3 tipos de vigas, una viga se la realizó sin traslape y la otras dos tienen una configuración de traslape de 0.13 m y 0.08 m, con las siguientes dimensiones de la viga son 0,75 m de longitud, 0.145 m de altura y 0.07 m de ancho, donde el elemento se lo diseño para que el esfuerzo a flexión afecte al acero. Mediante los ensayos realizados en laboratorio nos han permitido comprobar que la resistencia de las vigas ensayadas es mayor que la propuesta por modelos analíticos. Se ha constatado que la resistencia hasta llegar al punto de fisuración propuesta analíticamente es inferior a la obtenida experimentalmente. es_ES
dc.description.abstract The purpose of this work is to develop a theoretical-experimental analysis through normative and laboratory tests where the behavior of reinforced concrete beams with staggered overlaps is studied, starting from a base beam with predetermined type geometry, which is tested with a simply supported shape placed at a point load in the center of the beam that determines its deformation. The work is to compare the bending stresses by overlapping where 3 types of beams were made, one beam was made without overlapping and the other two have an overlapping configuration of 0.13 m and 0.08 m, with the following dimensions of the beam are 0.75 m long, 0.145 m high and 0.07 m wide, where the element was designed so that the bending stress affects the steel. Laboratory tests have allowed us to verify that the strength of the tested beams is higher than that proposed by analytical models. It has been found that the resistance up to the cracking point proposed analytically is lower than the one obtained experimentally. es_ES
dc.format.extent 37 p. es_ES
dc.language.iso es es_ES
dc.rights openAccess es_ES
dc.rights.uri https://creativecommons.org/licenses/by-nc-sa/3.0/ec/ es_ES
dc.subject HORMIGON ARMADO es_ES
dc.subject TRASLAPE es_ES
dc.title <B>análisis teórico experimental del comportamiento a flexión de vigas de hormigón armado mediante traslapes ineficientes de forma escalonada</b> es_ES
dc.type bachelorThesis es_ES
dc.email jcvalenciag_est@utmachala.edu.ec es_ES
dc.cedula 0705629814 es_ES
dc.utmachtitulacion.titulacion Examen complexivo es_ES
dc.utmachbibliotecario.bibliotecario Peralta Mercy es_ES
dc.utmachproceso.proceso PT-171022 (2022-2 TC) es_ES


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

openAccess Excepto si se señala otra cosa, la licencia del ítem se describe como openAccess