Repositorio Dspace

Análisis de vulnerabilidad sísmica de la unidad educativa colegio de bachillerato Machala en la Ciudad de Machala

Mostrar el registro sencillo del ítem

dc.contributor.advisor Zarate Encalada, José Marcelo
dc.contributor.author Granda Luna, Jonathan Alexander
dc.date.accessioned 2020-12-21T04:20:21Z
dc.date.available 2020-12-21T04:20:21Z
dc.date.issued 2020
dc.identifier.other ECFIC-2020-IC-DE-00033
dc.identifier.uri http://repositorio.utmachala.edu.ec/handle/48000/15864
dc.description El presente trabajo tiene como objetivo principal establecer la vulnerabilidad sísmica de los bloques del Colegio de bachillerato Machala de la ciudad de Machala mediante la normativa que nos proporciona la NEC en su Guía para evalación sísmica y rehabilitación de estructuras la cual está basada en el Manual de chequeo rápido de edificios para potencial amenaza sísmica planteado por la Federal Emergency Management Agency FEMA P-154. La metodología aplicada es cualitativa por lo tanto para calificar la estructura se necesita realizar una inspección visual donde se tiene en cuenta sus características generales como aspecto de la edificación, número de pisos, presencia de patologías, irregularidad de planta y en elevación, efecto de columnas cortas, tipo de suelo, año de construcción y otros aspectos que se observen en la inspección de campo. Una vez realizada la inspección se suman los puntos y se obtiene un puntaje que determina el grado de vulnerabilidad sísmica S, si este valor es menor o igual a 2 consideramos a la estructura de alta vulnerabilidad sísmica por lo tanto es necesario una evaluación especial es_ES
dc.description.abstract The main objective of this paper is to establish the seismic vulnerability of the blocks of the Colegio de bachillerato Machala of the city of Machala through the regulations provided by the NEC in the Guía para evaluación sísmica y rehabilitación de estructuras this is based on the Rapid Visual Screening of Buildings for Potential Seismic Hazards raised by the Federal Emergency Management Agency FEMA P-154. The applied methodology is qualitative therefore to qualify the structure it is necessary to carry out a visual inspection where its general characteristics are taken into account such as appearance of the building, number of floors, presence of pathologies, irregularity of plan and elevation, effect of short columns, type of soil, year of construction and other aspects that are observed in the field inspection. Once the inspection is carried out, the points are added and a score is obtained that determines the degree of seismic vulnerability S. If this value is less than or equal to 2, we consider the structure of high seismic vulnerability, therefore a special evaluation is necessary. es_ES
dc.format.extent 37 p. es_ES
dc.language.iso es es_ES
dc.rights openAccess es_ES
dc.rights.uri https://creativecommons.org/licenses/by-nc-sa/3.0/ec/ es_ES
dc.subject CUALITATIVA es_ES
dc.subject INSPECCIÓN VISUAL es_ES
dc.subject PATOLOGÍAS es_ES
dc.subject COLUMNAS CORTAS es_ES
dc.title Análisis de vulnerabilidad sísmica de la unidad educativa colegio de bachillerato Machala en la Ciudad de Machala es_ES
dc.type Examen Complexivo es_ES
dc.email jonathangranda_est@utmachala.edu.ec es_ES
dc.cedula 0704759000 es_ES
dc.utmachtitulacion.titulacion Examen complexivo es_ES
dc.utmachbibliotecario.bibliotecario Peralta Mercy es_ES
dc.utmachproceso.proceso PT-200720 (2020-1) es_ES


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

openAccess Excepto si se señala otra cosa, la licencia del ítem se describe como openAccess

Buscar en DSpace


Búsqueda avanzada

Listar

Mi cuenta

Estadísticas